Old PC will not boot with iodd Virtual CD-ROM.
The problem can be resolved with the following three methods. 1. If in DUAL-MODE, change to the CD-MODE. 2. Use external power source to USB cable (with USB Y-Cable) 3. If the PC have a built-in CD-ROM, remove that in the way of physical, or disable that in the BIOS
The updater says “Device does not matched.”
1. disconnect all other USB devices connected to your PC. 2. remove IODD cover. 3. press the tact switch on the PCB and hold, and connect USB. 4. wait for 3 second and release the switch. 5. run the firmware updater.
How do i get the list of ISOs to show up in LCD?
1. Initialize drive as MBR. 2. Format the first partition as NTFS or FAT32 or EXFAT. (There are two kinds of firmware, one for NTFS, the other for FAT32 and EXFAT) 3. Make '_iso' folder in root dir on first partition. 4. Copy *.iso or folder tree to the '_iso' folder. 5. Do safely removal. [...]
LCD display ‘1st partition’ or ‘unsupported partition’ and can not be used any function
Q)LCD display '1st partition' or 'unsupported partition' and can not be used any function A)There are two kinds of firmware, one for NTFS, the other for FAT32 and EXFAT.Format the first partition as NTFS or FAT32 or EXFAT, appropriately.
How to unlock write protection in virtual drive (VHD)
Q)How to unlock write protection in virtual drive (VHD) A)Change the mode of VHD according to VHD name ( example below ) filename.vhd => filename&D.vhd : dual mode filename.vhd => filename&DW.vhd : dual mode , write-enabled
Firmware update won’t do well.
Q)Firmware update won't do well. A)Remove all USB device except IODD. Connect IODD to rear PORT with short cable.
Display ‘too many files’ in the lcd screen
Q)Display 'too many files' in the lcd screen A)About NTFS firmware there is 32 lists limit. About FAT firmware there is no limit.
It Shows ‘Err (or gErr) : xxx’.
Q)It Shows 'Err (or gErr) : xxx'. A)Try in the following order 1. Press and hold the Jog Switch, and connect USB. 2. Check Drive. 3. Make new _ISO folder (after rename old _ISO to other) 4. Format HDD 5. Retry Firmware-Update
It Shows ‘IODD 2531’ or ‘IODD 2541’ only.
Q)It Shows 'IODD 2531' or 'IODD 2541' only. A)Check following steps. In case hardware problem. 1. Plug USB cable to rear port. (due to low power) 2. Change USB cable. 3. Reboot PC. 4. Change HDD. ( due to bad HDD). 5. Connect direct to USB port. not using USB HUB. 6. Connect another [...]